46922
Accession Number
16272
Title Of Article Chaper
Indoor air pollution: effects on cultural and historical materials
Title Of Journal Book
The international journal of museum management and curatorship
Volume
4
Issue
1
Pages
44459
Collation
3 tables, 73 refs.
ISBN
0260-4779
Language Of Text
English
Literature Type
Serial
Literature Level
Analytic
Abstract
Although the development of central air-conditioning systems some 50 years ago caused substantial attention to be paid to the effective control of the museum environment, interest in air pollution damage to art works predates that development. They discuss individual pollutants (sulfur oxides, nitrogen oxides, etc) as well as categories of indoor pollutants (those emitted from building materials, those emitted by artifacts, etc.). Tables provide data on air quality criteria for museums, archives, and libraries, as well as indoor air pollution damages to specific materials. See also preceding abstract.
Keywords
Pollutant sulfur oxide;Pollutant nitrogen oxide;Museum air pollution; Museum air conditioning;Air pollution measurement AATA -- AATA