A Study on Evaluation of Effects on Air Supply Openings from Exhaust Gases in equipped with Latent Heat Condensing Boilers (R1-TS53-PP01)
Title Of Journal Book
Clima 2010: 10th REHVA World Congress: Sustainable Energy Use in Buildings: 9-12 May, Antalya, Turkey
Collation
7 p. : ills.
Reference Bibliography
Includes bibliographic references
Language Of Text
English
Literature Type
Monograph
Literature Level
Analytic
Abstract
In Japan, when installing latent Heat Condensing Boilers in multi-family housing, it is currently common to install them outside of open hallways but the exhaust gas temperature is low and the risk of residual gas accumulating due to a decrease in natural ventilation capacity is increasing. In order to collect data to inform setting of policy for equipment installation standards related to positioning of the air supply inlets during normal ventilation when installed in open corridors, experiments using full-size models and investigations using CFD were conducted. It was confirmed that use of a reducer to improve the exhaust resulted in an improvement in accumulation of exhaust gases in corridors, and the concentration of gases was lowered at the air supply inlet. Further, air supply inlet concentrations change according to the relationships between the heights of the ceiling, handrails, and heat source devices; corridor width also has an effect.
Keywords
evaluation;effect;exhaust;gas;air;heat