35775
Author
Kenjo, Toshiko
Title Of Article Chaper
Hikari Monita no riyo Tenjishomei no anzen na shiyo no tame ni
Title Of Journal Book
Hozon Kagaku
Issue
25
Pages
37-42
Publisher
Tokyo National Research Institute of Cultural Properties
Publisher City
Tokyo
ISSN
0287-0606
Language Of Text
Japanese
Literature Type
Serial
Literature Level
Analytic
Abstract
Photomonitoring strips recently developed by the present author were exposed for 50 hours to 4 light sources usually used for exhibitions at various illuminances and color differences (DELTAE) were measured from the original. The illuminances required for causing a given DELTAE (about 6) after 50 hours'exposure are in the following order: Non-UV fluorescent lamp (color temperature 4500°k) Ü0 non-UV fluorescent lamp (color temperature 3000°k)Ü0Ü0 incandescent lamp (with cold mirror) Ü0 incandescent lamp. The monitoring strips showed that the color difference caused by the exposure to a light source was reduced by 10 C4 30% through a sheet of glass, without significant change in illuminance. The author, therefore, states that even non-UV fluorescent lamps can be used safely for illuminating works of art when used through a sheet of glass. -- AATA
Keywords
Photomonitoring strip; Illumination; Non-UV fluorescent lamp AATA
pub_id
35775
Title Translation
Utilization of photomonitoring strips to the safe use of illuminations for exhibitions