24623
Accession Number
9657
Author
Heydorn, K.
Title Of Article Chaper
Determintion Of The Specific Activity Of Commercial Iodine-125 Preparations By Neutron Activation Analysis
Title Of Journal Book
PREPRINTS; The 1968 International Conference Modern Trends In Activation Analysis. National Bureau Of Standards
Pages
1009-1015
Literature Level
Analytic
Abstract
The precision of an activation analysis method prescribes the estimation of the precision of a single analytical results. The adequacy of these estimates to account for the observed variations between duplicate results from the analysis of different samples and materials, is tested by the statistic T, which is shown to be approximately by a chi-squared distribution. Application of this test to the results of determinations of manganese in human serum by a method of established precision, led to the detection of airborne pollution of the serum during the sampling process. The subsequent improvement in sampling conditions was shown to give not only increased precision, but also improved accuracy of the results.
Keywords
neutron;statistical;analysis;sampling;precision
pub_id
24623