22172
Accession Number
37013
Title Of Article Chaper
Predicted gas loss of sulfuryl fluoride and methyl bromide during structural fumigation
Title Of Journal Book
Journal of Stored Products Research
Volume
44
Issue
1
Pages
44206
Collation
10 p. : ills.
Reference Bibliography
Includes bibliographic references
Language Of Text
English
Literature Type
Serial
Literature Level
Analytic
Abstract
Elimination of insects in grain-milling facilities requires the periodic use of a gaseous insecticide (fumigant) that can destroy pests. Ideally, the fumigant concentration within a treated building should remain constant during the fumigation process to enhance efficacy while minimizing the amount of fumigant required. However, fumigant is often slowly lost through cracks and crevices within the structure. Wind impact on this leakage loss and in natural ventilation is explored using computational fluid dynamics (CFD). Two surrogate enclosure geometries, based on actual commercial grain mills, are used in the analysis. Building materials are assumed impermeable to fumigants, and cracks within structures are approximated as square regions where permeability parameters can be specified (i.e., porous jumps). Half-loss times (HLT) for sulfuryl fluoride (SF) and methyl bromide (MB) within the structure can be simulated. When diffusion dominates (no wind), SF had increased leakage rates of similar to 5.4% over MB. However, simulated HLT due to diffusion are in the order of years for both fumigants. If the wind is blowing at measurable rates, convection-driven losses dominate and leakage from the mill is independent of the fumigant being used. Predicted half-loss times for MB and SF are statistically indistinguishable for external wind velocities from 0.125 to 8 m s(-1). Therefore, HLTs are insensitive to fumigant physicochemical properties when the wind is blowing. Representative and diverse wind-frequency analysis for California and Texas show limited intervals of calm wind periods, and median wind speeds at or above those investigated in this analysis. Thus, decisions for product use should be based on efficacy, cost, and environmental impact, since convective-induced leakage rates are similar.
Keywords
fumigation;methyl;bromide;sulfate;fluoride;leakage
pub_id
22172